How is chiller part-load ratio calculated?

How is chiller part-load ratio calculated?

The part-load ratio of the indirect absoprtion chiller’s evaporator is simply the actual cooling effect required (load) divided by the maximum cooling effect available.

How do you evaluate a chiller performance?

Calculating the efficiency of a chiller is fairly simple. It is measured in “COP” which stands for Coefficient Of Performance. The Coefficient of performance is just a ratio of the refrigeration effect produced by the chiller against the amount of electrical energy that went into the machine to produce this.

How much electricity does a chiller consume?

They can consume approximately 20 percent of a building’s total electricity. Inefficient chillers can waste significant amounts of electricity, and even modest improvements in efficiency may yield substantial energy savings and attractive paybacks.

What is part load performance?

2.4. 1.2 Partial Load Performances. In most of the annual cooling and heating periods, an HP is operated under the indoor thermal load lower than its rated capacity; this situation is called partial load operation.

What is the efficiency of a chiller?

Chillers use approximately 20% of the total electrical power generated in North America and the U.S. Department of Energy estimates that chillers expend up to 30% in additional energy through inefficiency.

Does chiller use a lot of electricity?

Chillers consume more than 40% of the total energy used in the commercial and industrial buildings for space conditioning. It has been estimated that about 8368 MWh annual energy can be saved by using efficient chillers at different loadings.

What is chiller plant efficiency?

Whereas a typical packaged cooling unit has an efficiency of 1.1 to 1.4 kW/ton, a chiller-based system can have a full load efficiency that is far lower—values of 0.8 to 1.0 kW/ton for the entire chiller plant are typical.

How much does the Chiller cop rise with part load?

The chiller COP can rise by up to 111.9% when the chiller load and outdoor temperature are low. The improved part load performance is due to a situation where the heat rejection airflow is enhanced to decrease the condensing temperature.

Do air-cooled centrifugal chillers perform well in commercial buildings?

Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model.

What is a high-efficiency chiller?

High-efficiency chillers can produce chilled water using less than 0.50 kW per ton of cooling capac- ity. A refrigeration system must also reject the heat that it removes using a cooling tower for water cooling the condenser (most efficient) or using fans for air cooling the hot refrigerant of the condenser coil. Chiller Performance Ratings

What is the coefficient of performance of an air-cooled heat rejection system?

Yet the air-cooled heat rejection system is less efficient than the water-cooled counterpart. The coefficient of performance (COP) of air-cooled chillers is 2.7–3.2 at full load while that of water-cooled chillers is 4.2–5.4 at full load [4]. The COP is defined here as the cooling capacity over chiller power input, both in kW.